We carry out EICRs across Bristol and South Gloucestershire. An EICR is an inspection and test of the fixed electrical installation in a property. We are an NICEIC Approved Contractor, our reports are issued in accordance with BS 7671, and you get a fixed price quote before we book the visit.






LA Electrical & Solar is a family-run electrical business providing Electrical Installation Condition Reports (EICRs) for homeowners, landlords, letting agents and commercial property owners across Bristol and South Gloucestershire.
Our qualified electricians carry out comprehensive electrical inspections and periodic testing, assessing the condition of fixed wiring, consumer units, earthing, bonding and protective devices. We identify electrical deterioration, potential safety hazards and issues that may not meet current BS 7671 wiring regulations.
If the report finds something that needs attention, we explain it in plain terms and quote for the remedial work. You are free to use us for that work or not.
As a NICEIC Approved Contractor and Which? Trusted Trader, we bring decades of electrical expertise to every inspection, helping property owners meet their electrical safety responsibilities and maintain safe installations.
The inspection is the same. What changes is why you need it, how often, and what you have to do with the report.
A legal requirement for rented homes in England. The installation must be inspected and tested at least every five years.
A mortgage survey does not tell you whether the electrics are safe. An EICR before you complete does.
There is no legal requirement if you live in your own home. The standard recommendation is every 10 years.
Employers must keep electrical systems safe under the Electricity at Work Regulations 1989. An EICR is the usual way to show it.
Three EICR services, each with its own page, and the work we can carry out if a report finds a problem.
EICRs for rented homes, with the report you need to give your tenants. We test for landlords in Bradley Stoke, Filton, Horfield, Thornbury and across the area.
An independent check of the electrics before you commit to a purchase, so you know about any remedial work in advance.
Inspection and testing for offices, industrial units and community buildings. We have tested an industrial unit in Thornbury and Almondsbury Village Hall.
If your report lists C1, C2 or FI observations, we can trace the fault and carry out the repair.
An old fuse board without RCD protection is a common reason for an unsatisfactory report.
Where an EICR shows the wiring has reached the end of its life, we can advise on a full or partial rewire.
We inspect and test the fixed electrical installation: the parts of the system that stay with the building. Appliances you plug in are not part of an EICR.
We check the wiring, sockets, switches, light fittings and the consumer unit for damage, wear and signs of overheating.
We test each accessible circuit to confirm it is safe and performing as it should.
We assess the earthing and bonding arrangements, which protect you if a fault occurs.
Each observation on the report is given a code. A report is satisfactory when it has no C1, C2 or FI observations. Our guide explains what the classification codes mean.
There is a risk of injury now. It needs making safe straight away.
Not dangerous at this moment, but it could become so. It needs remedial work.
It does not meet the current standard, but it is not unsafe. The report can still be satisfactory.
Something could not be confirmed during the inspection and needs looking at more closely.
It depends on the type of property and how it is used. See our guide to how often you should get an EICR.
At least every five years. This is the law for rented homes in England, and your tenants must be given a copy of the report.
Every 10 years is the standard recommendation, or when the property changes hands.
There is no fixed interval in law. Most premises are inspected every five years, and industrial units every three to five.
Tell us the type of property and how many consumer units it has. We give you a fixed price for the inspection.
Our electrician inspects and tests the installation. The power is switched off for parts of the visit.
You receive the EICR, with each observation coded and explained.
If anything needs putting right, we give you a fixed price for the work.
Our inspection and testing is carried out under our NICEIC registration.
Every EICR is issued in accordance with BS 7671, the UK wiring regulations.
If the report finds faults, our own electricians can put them right, so you deal with one company.
We are based in Easter Compton and test properties across Bristol and South Gloucestershire every week.
Reviews from customers across Bristol and South Gloucestershire who have used LA Electrical & Solar.
Four inspections we have carried out locally, followed by other recent work from our team.
Landlord EICR on a rented home ahead of a continued tenancy.
Homebuyer EICR carried out before the purchase completed.
Commercial EICR at an industrial unit.
Commercial EICR at Almondsbury Village Hall.
We carry out electrical inspection and testing across Bristol, North Bristol and South Gloucestershire, including BS6 to BS11, BS32 and BS34 to BS37. Recent EICRs include Bradley Stoke, Filton, Horfield, Thornbury, Winterbourne and Olveston. See also EICR in Yate.
Donโt see your location listed? Get in touch with us. We also work across the wider Bristol area.
Tell us the type of property and when it was last tested. We will tell you what you need.
An Electrical Installation Condition Report. It is an inspection and test of the fixed wiring, consumer unit, earthing and accessories in a property, carried out to BS 7671. It is often called an electrical safety certificate.
Yes. Landlords in England must have the electrical installation in a rented home inspected and tested at least every five years by a qualified person, and give tenants a copy of the report. See landlord EICR.
There is no legal requirement if you live in your own home. The standard recommendation is every 10 years, or when the property changes hands.
Yes. We inspect properties before a purchase completes. See homebuyer EICR.
It depends on the size of the property and the number of consumer units. We give you a fixed price before we book. See our guide to EICR costs.
The report lists what needs putting right. For rented homes, landlords must have the remedial work or further investigation completed within 28 days, or sooner if the report says so. We can quote for the work.
C1 means danger present. C2 means potentially dangerous. C3 means improvement recommended. A report with any C1 or C2 observation is unsatisfactory. See EICR codes explained.
It depends on the size of the property and the number of circuits. See how long an EICR takes.
There is no fixed interval in law. Most commercial premises are inspected every five years, and higher-risk sites more often. Your insurer may set its own interval. See commercial EICR.
Yes. If the report finds faults, we can carry out the remedial work. See electrical repairs.