LA Electrical & Solar

Landlord EICR in Bristol

Electrical safety reports for rented homes

We carry out landlord EICRs for rented homes across Bristol and South Gloucestershire, as part of our EICR testing in Bristol. You get the report your tenants are entitled to, a fixed price before we book, and one contractor for any remedial work. We are an NICEIC Approved Contractor.

5 years
Maximum Interval
28 days
To Complete Remedial Work
NICEIC
Approved Contractor
Electrical Fault Finding
For Landlords
A report copy for your tenants
Who We Are

Landlord EICRs from a Local NICEIC Contractor

If youโ€™re a landlord in Bristol looking for a reliable, straightforward EICR, we can help. We carry out electrical safety inspections for rental properties across Bristol and the surrounding areas, with fixed pricing, no fuss and a detailed report upon completion.

We inspect and test fixed wiring, consumer units, sockets and protective devices, providing a comprehensive Electrical Installation Condition Report (EICR) with clear recommendations for any necessary remedial work.

We regularly work across Bristol (BS1โ€“BS11), including Park Street, Whiteladies Road and Clifton Down, helping landlords, letting agents and property managers meet their legal electrical safety responsibilities.

Your Legal Duties

What the Law Requires of Landlords

The Electrical Safety Standards in the Private Rented Sector and Social Rented Sector (England) Regulations 2020 apply to most rented homes in England. They set four main duties.

Inspect at Least Every Five Years

The electrical installation must be inspected and tested at intervals of no more than five years, or sooner if the last report sets an earlier date.

Inspect Before a Tenancy Begins

The installation must have been inspected and tested before a new tenancy starts. A report that is still in date meets this.

Use a Qualified Person

The inspection must be carried out by someone competent to inspect, test and carry out any remedial work to the wiring regulations.

Act on the Report

Where the report requires remedial work or further investigation, it must be completed within 28 days, or sooner if the report says so.

The Report

Who Gets a Copy of the EICR, and When

The regulations set a deadline for each person who is entitled to the report. You must also keep a copy to give to whoever carries out the next inspection.

Existing Tenants

Within 28 days of the inspection and test.

New and Prospective Tenants

A new tenant must have a copy before they move in. A prospective tenant must have one within 28 days of asking in writing.

The Local Authority

Within 7 days of a written request from the local housing authority.

If It Fails

What Happens If a Landlord EICR Is Unsatisfactory

A report is unsatisfactory when it contains a C1, C2 or FI observation. Our guide explains what the EICR codes mean. For a rented home, three things follow.

Danger Is Made Safe

A C1 observation means danger is present. We make the circuit safe before we leave, or tell you how to isolate it.

Remedial Work Within 28 Days

Remedial work or further investigation must be completed within 28 days of the inspection, or within any shorter period the report gives.

Written Confirmation

You need written confirmation that the work is done. It goes to your tenants and the local authority within 28 days of completion.

What We Do

Electrical Services for Landlords and Rental Properties

The work that most often follows a landlord EICR, and the other inspections we carry out.

Electrical Fault Finding in Thornbury

We carry out the remedial work listed on your report and give you written confirmation when it is complete.

Consumer Unit Replacement in Bradley Stoke

An old fuse board without RCD protection is a common C2 observation in rented homes. We replace it and certify the work.

Damaged electrical socket replaced at a property in Bradley Stoke, South Gloucestershire

Smoke and Heat Alarms

Smoke alarms are a separate duty for landlords, and often checked at the same time as the EICR.

Homebuyer EICR in Olveston

Buying a property to let. An EICR before you complete shows what the electrics will need.

commercial EICR

Inspection and testing for business premises, including shops and units you let commercially.

EV Charger Installation in Thornbury (MyEnergi Zappi Glo, Lower Morton)

EV Charging for Flats and Rentals

Charge points for rented homes and blocks of flats, with a landlord grant available.

How It Works

How a Landlord EICR Visit Works

1

We Arrange Access

We agree a date with you or your letting agent, and can contact the tenant directly to arrange access.

2

We Inspect and Test

Most rented homes take between one and three hours, depending on the size of the property and the number of circuits.

3

We Issue the Report

You receive the EICR with each observation coded, ready to pass to your tenants.

4

We Quote for Remedial Work

If the report is unsatisfactory, we give you a fixed price for the work and written confirmation when it is done.

Why LA Electrical

Why Bristol Landlords Choose Us for EICRs

We Test Rentals Every Week

Recent landlord EICRs include Bradley Stoke, Filton, Horfield, Eastville, Thornbury, Winterbourne and Olveston.

We Carry Out the Remedial Work

You keep the inspection, the repairs and the written confirmation with one contractor.

We Are an NICEIC Approved Contractor

Our reports are issued in accordance with BS 7671 under our NICEIC registration.

We Offer Portfolio Discounts

Multi-property discounts are available for landlords and agents with several properties.

Customer reviews

Real Reviews From Our Clients

Reviews from customers across Bristol and South Gloucestershire who have used LA Electrical & Solar.

Recent Work

Recent Landlord EICRs in Bristol and South Gloucestershire

Four landlord inspections we have carried out locally, followed by other recent work from our team.

Landlord EICR at a rented home ahead of a continued tenancy.

Landlord EICR at a rental property.

Landlord EICR at a rental property.

Landlord EICR with the report issued on the day.

Areas We Cover

Landlord EICRs near you in Bristol and South Gloucestershire

We carry out landlord EICRs across Bristol, North Bristol and South Gloucestershire, including BS6 to BS11, BS32 and BS34 to BS37. We inspect rented homes in Bradley Stoke, Filton, Horfield, Eastville, Thornbury, Winterbourne and Olveston.

Donโ€™t see your location listed? Get in touch with us. We also work across the wider Bristol area.

Helpful Informations

FAQs About Landlord EICRs

Matthew of LA Electrical & Solar

Need Help Deciding?

Tell us about the property and when it was last tested. We will tell you whether you are due.

At least every five years. If the last report sets an earlier date for the next inspection, that date applies.

Not if your current report is still in date. The installation must have been inspected before the tenancy begins, and the new tenant must be given a copy before they move in.

No. The property needs to be accessible, but the tenant does not have to be there. We can contact your tenant directly to arrange access.

Between one and three hours for most rented homes, depending on the size of the property and the number of circuits.

It depends on the size of the property and the number of consumer units. We give you a fixed price before we book, and multi-property discounts are available.

Remedial work or further investigation must be completed within 28 days, or sooner if the report says so. We can carry out the work and give you written confirmation.

A local housing authority can impose a financial penalty of up to £40,000 for a breach of the regulations.

Most homes in England let to a tenant as their only or main residence, including social housing. Exclusions include lodgers who share with the landlord, long leases, student halls of residence, and hostels and refuges.

Yes. Our own electricians carry out the repairs, so you deal with one contractor. See fault finding and repairs.

Landlord Guides

Our Guides for Landlords

We wrote these guides to answer the questions landlords and letting agents ask us most.

Guide

The requirement in plain terms.

Guide

What to do before the five years are up.

Guide

What happens next and how quickly.

Guide

What C1, C2 and C3 mean on your report.

Guide

What an EICR costs and how long it lasts.

Guide

How a plastic consumer unit is coded.

We use cookies

We use cookies to improve your experience on this website. You may choose which types of cookies to allow and change your preferences at any time. Disabling cookies may impact your experience on this website. You can learn more by viewing our Cookie Policy.